Specifications:
Discharge Current: 100A
Charging Current (Same Port): ≤60A
Main Circuit Conduction Internal Resistance: ≤5mΩ
Discharge Overcurrent Protection: 150A±10A
Product Size: 146x62x8.36±1mm
Overcharge Protection
Detection Voltage: 3.65±0.025V
Detection Delay Time: 1000±500ms
Discharge Voltage: 3.5±0.05V
Over Discharge Protection
Detection Voltage: 2.35±0.1V
Detection Delay Time: 1000±500ms
Unwind Voltage: 2.7±0.1V
Equalization Parameters
Detection Voltage: 3.5±0.025V
Detection Delay Time: 50±50ms
Equalization Current: 30±5mA
Overcurrent Protection
Detection Voltage: 12.8±15mV
Detection Delay Time: 1000±500ms
Current Protection: 100±10A
Short Circuit Protection
Trigger Condition: External Short Circuit
Detection Delay Time: ≤300µs
Release Condition: Disconnect the Load
Temperature Control Protection
Charging High Temperature Protection Detection Temperature: 75°C
Discharge High Temperature Protection Detection Temperature: 75°C
Discharge Condition: 65°C
Self-Power Consumption